How the flow number is made
Last checked
The number
Flow at the Bennett Spring put-in is computed, not measured. No gauge sits on the river between the spring and Prosperine.
How it is computed
Two public gauges, read every fifteen minutes:
- Niangua River at Windyville (USGS 06923250), upstream of the spring.
- Bennett Spring (USGS 06923500), the spring's own discharge.
The two are added, and that is the whole method. Both numbers appear next to the total so the arithmetic can be checked.
When it is withheld
If no complete total exists, the number is withheld. When a gauge drops out after a good reading, the last complete total is shown with the time it was read, and marked stale. Half a sum is never published.
What it leaves out
Small tributaries between Windyville and the spring are not gauged, so the total is a little low. Travel time between the two gauges is not accounted for, which matters for a few hours during a rise and not much otherwise.
The percentile
Each reading is compared with every day in the same month since 1991, using the same two gauges. "62% of November days were lower" says where today sits in the record. It does not say whether the river is floatable.
The bands
The band table is not published yet. The thresholds behind it have not been checked against a season of real water, so the conditions page shows the number and the percentile and leaves the judgement alone.